Pentra DX Nexus SPS Evolution

Be productive and flexible, create quality

  • Autoloader with continuous loading capability
  • Rack compatibles with most pre and post analytical systems
  • Automatic reflex testing
  • Double DIFF Matrix
  • Body fluids
  • Expert validation station
  • DHSS technology
Segment: Medical
Division: Hematology
Manufacturing Company: HORIBA ABX SAS

Pentra DX Nexus

  • Methods of measurement: flow cytometry, Cytochemistry, Impedance, absorbance, Optical cytometry and fluoro-flowcytometry
  • QuaDimension concept : automatic correction of the leucocyte count based on 4 independent principles
  • DHSS: focused flow cytometry and sequential measurement (impedance and absorbance)
  • Automatic reflex testing: selective and programmable (hematology parameters, alarms and flags, demography)
  • Rack rotation mixing of samples: smooth and efficient
  • Quality: complete traceability for each run in compliance with the accreditation requirements


SPS Evolution

  • Drop needle system: Auto-cleaning drop needle system. Calibration of blood drop
  • Smearing system: No inter-sampling contamination, No carry-over, Easy to replace
  • Stainer: Choice of Stain: MGG, Wright, Wright Giemsa. Programmable staining protocol

Technical

Weight

170 kg

Power requirements

100 to 240 V

50 Hz to 60 Hz - 800 VA

Dimensions

73 x 170 x 55 (H x W x D) cm

Printer

Laser

Throughput

120 tests/hour

Data processing

Color LCD 12.1 in

5 x USB1, RS232C, Mono and Bi-directional connection

Compliance

ASTM protocol

 

Samples

Parameters  (50)

 WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, *PCT, *PDW %, NEU, LYM, MON, EOS, BAS, *ALY, *LIC, *IMM, *IML, *IMG: (% and #), RET (% and #), RETH %, RETM %, RETL %, *IMR %, CRC%, IRF, MRV, *RHCc, MFI, NRBC % NRBC#, *CWBC, *WBC#, *RBC#, *PolyNuc#, *MonoNuc#
*RUO (Research Use Only)

Volume

Manual mode: 130 µL
Automatic mode: 200 µL 

Stability

Up to 48 hours for CBC/DIFF

Operating sample mode

Autoloader 15 racks (150 tubes) capacity
Continuous feed for 8-racks, 160 slides capacity
Sample mixing with end-over-end rack rotation
Open tube in STAT mode

Identification

Alphanumeric, Bar-code reader (internal and external)
Automatic 3-line printing on the slide using indelible ink

 

Results

Parameters

Presicion (CV %)

Linearity

WBC

< 2

0 - 150 x 103 / mm3

RBC

< 2

0 - 8 x 106 / mm³

HGB

< 1

0 - 24 g/dL

HCT

< 2

0 - 67%

PLT

< 5

0 - 1900 x 103 / mm3

PLT (PLT concentrate)

 

0 - 2800 x 103 / mm3

LYM

< 5

--

MON

< 10

--

NEU

< 3

--

EOS

< 15

--

BAS

< 20

--

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Product accessories

Accreditation Folder (ISO)
Accreditation Folder (ISO)

Accreditation Support

CellaVision®
CellaVision®

Digital Cell Morphology Systems

Hematovision
Hematovision

Accreditation Support

Quality Control Program (QCP)
Quality Control Program (QCP)

Accreditation Support