HE-960HI

Panel-mount type conductivity meter

Sanitary sensor lineup

A conductivity meter for measuring a wide range from production water up to 500 mS/cm and enabling advanced concentration control with abundant outputs. Offering a lineup that includes sanitary sensors which no uneven surfaces and are stain resistant. The use of a panel mount converter allows for cost reduction at the time of installation.

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

Diverse lineup of sensors available

The sensor has a smooth structure without irregularities, providing resistance to dirt and less prone to contamination.  Durable even under high pressure and high temperature conditions, making it ideal for chemical management in food production lines after CIP/SIP (Clean-in-Place/Sterilize-in-Place) processes.  With two types of sensors: flow-through (inline) type, which is integrated into the pipeline, and insertion type, which is inserted into the pipe, various sizes and fittings to accommodate different requirements are available.

Possible to be used in a panel-mounted configuration.

This transducer is easy to install while providing standard functions.

Product nameConductivity meter
ModelHE-960HI
Measuring methodFour-electrode type
Cell constant0.1/cm
Temperature sensor
specifications
Resistance thermometer bulb 1000 Ω/0℃
Measuring rangeConductivity0 mS/cm to 200 mS/cm (measuring range of conductivity before temperature compensation: 0 mS/cm to 500 mS/cm)
Temperature0.0℃ to 100.0℃
Concentration
conversion
HNO30% to 5.00%Preprogrammed in the instrument
NaOH0% to 5.00%
H3PO40% to 5.00%
Option 10% to 100.00%Conversion formula is defined by user (temperature compensation and concentration conversion)
Option 20% to 100.00%
Repeatability0.000 mS/cm to 2.000 mS/cmWithin ±0.5% full scaleUsing equivalent input for conductivity with 10 m cable
0.00 mS/cm to 20.00 mS/cmWithin ±0.5% full scale
0.0 mS/cm to 200.0 mS/cmWithin ±0.5% full scale
0 mS/cm to 500 mS/cmWithin ±1.0% full scale
0.0℃ to 100.0℃Within ±0.2℃
Linearity0.00 mS/cm to 20.00 mS/cmWithin ±0.5% full scaleUsing equivalent input for conductivity with 10 m cable
0.0 mS/cm to 200.0 mS/cmWithin ±1.0% full scale
0 mS/cm to 500 mS/cmWithin ±2.0% full scale
0.0℃ to 100.0℃Within ±0.5℃
Display and output
range:
Conductivity0 mS/cm to 2000 mS/cm
Temperature−30℃ to 160℃
Concentration0% to 5%: NaOH, HNO3, H3PO4
0% to 100%: Concentration of the component in the optional conversion formula set by user
Transmission outputNumber of output points: 4
4 mA to 20 mA DC: input/output isolated type
Maximum load resistance: 900 Ω
Transmission output range: Freely selectable within the measurement range
(Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.)
For Cur4, the transmission output can be changed by external input.
Contact outputNumber of outputs points: 5
Alarm contact output (R1 to R4)
 Contact type: Relay contact, SPST (1a)
 Contact capacity: 240 V AC, 1 A and 30 V DC, 1 A (resistance load)
 Contact function: Selectable from the upper/lower limit action (ON/OFF control), delay, and hysteresis
 Contact action: closed during control operation (error setting), opened normally and while the power is down
 (However, R1 and R2, R3 share the COMMON contacts respectively.)
Anomaly alarm output (RF)
 Contact type: Relay contact, SPDT (1c)
 Capacity: 240 V AC, 1 A and 30 V DC, 1 A (resistance load)
 Contact function: Selectable from error, anomaly alarm, and maintenance.
 Contact action: When the C-NO contact is used, it is closed during the normal operation or opened when an error occurs (including the case where the power is turned OFF).
 (The C-NC contact acts inversely to the C-NO contact.)
 (However, R4 and RF share the COMMON contacts respectively.)
Contact inputNumber of input points: 2
 Contact status: Type-A contact with open collector being of no-voltage
 Contact functions: Transmission output range selection and external input for Hold
 (Select either “Transmission 4 range selected” or “Transmission 2 range selected + Hold”)
Communication
output
The RS-485 input/output
Calibration functionConductivity: Based on the specified compensation coefficient for the cell constant (parameter input)
Temperature: Calibrated by comparing with the reference thermometer
Transmission output
hold feature
Selectable from the Previous value hold and the Optional value hold (however, only the previous value hold is available in the maintenance mode.)
Self-diagnosis
function
  • Sensor diagnosis (short-circuit and disconnection of the temperature sensor)
  • Converter error
Temperature
compensation
  • Temperature characteristics of NaCl (reference temperature: 25℃)
  • Arbitrary temperature coefficient entry (reference temperature: 25℃, temperature coefficient: 0%/℃ to 5%/℃)
  • No temperature compensation is performed.
Temperature
compensation range
0℃ to 100℃ (a temperature less than 0℃ and more than 100℃ is calculated as an extension of the range)
Ambient temperature−5℃ to 55℃
Relative humidity20% to 85% (without dew condensation)
Storage temperature−25℃ to 65℃
Power supplyRated voltage 100 V to 240 V AC, 50/60 Hz, 20 VA (max.)
StructureIndoor-use panel installation type
Panel case: ABS, Terminal: PBT, Panel: IP65 dust and water proof structure
Protective structurePanel: IP65 (IEC60529, JIS C0920), Rear case: IP20, Terminal:IP00
Class II device (IEC61010-1), Pollution level 2 (IEC61010-1)
Conforming standardsCE MarkingEMC Directive: EN61326-2-3
Low Voltage Directive: EN61010-1
FCC RuleFCC Part15
External dimensions96 (W) mm × 96 (H) mm × 115 (D) mm
Case depth: approx. 105 mm (when panel-mounted)
MassApprox. 550 g
Compatible sensorsSubmersible FES-2XX series sanitary four-electrode conductivity sensor
Flow-through FES-310 series sanitary four-electrode conductivity sensor

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

514-22
514-22

1.41 mS/cm Conductivity Standard Solution

514-23
514-23

12.9 mS/cm Conductivity Standard Solution

9371-10D Conductivity Cell
9371-10D Conductivity Cell

Conductivity Cell for Ultra Pure Water Measurement

CS-600F
CS-600F

Fiber Optic Type Chemical Concentration Monitor

CS-620F
CS-620F

Optical Fiber Type Hot Phosphoric Acid Concentration Monitor

CS-900
CS-900

Non-Contact Chemical Concentration Monitor

HC-200F
HC-200F

Field-installation Type Fluoride Ion Concentration Meter

HC-200NH
HC-200NH

Field-installation type ammonia nitrogen meter

HC-300F
HC-300F

Field-installation Type Fluoride Ion Concentration Meter

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-200FL
HD-200FL

Field-installation type optical dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HD-200
HD-200

Field-installation type dissolved oxygen meter (DO meter)

HD-300
HD-300

Field-installation type dissolved oxygen meter (DO meter)

HD-480
HD-480

Panel-mount type dissolved oxygen meter (DO meter)

HD-960L
HD-960L

HF (Hydrofluoric Acid)  DO (Dissolved Oxygen) Monitor / Pure Water DO (Dissolved Oxygen) Monitor

HD-960LR
HD-960LR

Dissolved Oxygen Concentration Monitor Series for Semiconductor Manufacturing

HE-200C
HE-200C

Field-installation type electric conductivity meter (conductivity meter)

HE-200H
HE-200H

Field-installation type electric conductivity meter

HE-200R
HE-200R

Field-installation type electric resistivity meter (resistivity meter)

HE-300C
HE-300C

Field-installation type electrical conductivity meter (conductivity meter)

HE-300R
HE-300R

Field-installation type electric resistivity meter (resistivity meter)

HE-480C
HE-480C

Panel-mount type conductivity meter (conductivity meter)

HE-480C-GC
HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
HE-480H

Panel-mount type conductivity meter (conductivity meter)

HE-480R
HE-480R

Panel-mount type resistivity meter (resistivity meter)

HE-480R(W)
HE-480R(W)

Resistivity Meter for Semiconductor Cleaning Processes

HE-960CA
HE-960CA

Citric Acid Monitor

HE-960CW
HE-960CW

Panel-mount type 2-channel conductivity meter (conductivity meter)

HE-960H-KOH
HE-960H-KOH

KOH Monitor

HE-960H-TM
HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960LC
HE-960LC

Carbon Sensor Conductivity Meter

HE-960LF / FS-09F-1/2
HE-960LF / FS-09F-1/2

Flat Carbon Sensor Conductivity Meter

HE-960R-GC
HE-960R-GC

Carbon Sensor Resistivity Meter

HE-960RW
HE-960RW

Panel-mount type 2-channel electric resistivity meter (resistivity meter)

HE-960RW-GC
HE-960RW-GC

2-Channel Resistivity Meter

HF-700A
HF-700A

Low Concentration Monitor- Sulfuric Acid/Hydrogen Peroxide

HF-960H
HF-960H

HF / HCl Concentration Monitor

HF-960M
HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HO-200
HO-200

Field-installation type ORP meter

HO-300
HO-300

Field-installation type ORP meter

HO-480
HO-480

Panel-mount type ORP meter

HR-200
HR-200

Field-installation type polarographic residual chlorine meter

HR-200RT
HR-200RT

Field-installation type residual chlorine meter

HR-480
HR-480

Panel-mount type galvanic residual chlorine meter

HT-110
HT-110

On-line TOC analyzer

HZ-960HPO-M
HZ-960HPO-M

H2O2 Monitor