Converter for peracetic acid monitor PM-960

PM-960

 

 

Continuous measurement of peracetic acid concentration for food filling machinery.

A measurement device for continuous measurement of the concentration of peracetic acid used for sterilization in food and beverage processing. The device uses no reagents and is maintenance-free.

 

 

 

Division: Process Water
Manufacturing Company: HORIBA Advanced Techno Co., Ltd.

 

  • Can measure concentrations from 0-4000mg/L
  • Reagent-free continuous measurement
  • Easy-to-replace sensor (no service engineer required)
  • Panel-mounted display enables remote operation
  • IP65 compliant display (when mounted on wall)
  • 4-20mA output and RS-485 communication
    5 contact outputs

Configuration

Usage Examples

Examples of Peracetic Acid Monitoring
(1) Checking concentration during adjustments
(2) Checking concentration during supply
(3) Checking concentration during return

 

Converter

Product nameConverter for peracetic acid monitor※1
ModelPM-960
Temperature compensation elementPlatinum resistance thermometer (Pt1000) 1000 W at 0℃, 3850 ppm/℃
Measurement range100 to 4000ppm (0.010 to 0.400%)
Repeatability±100ppm
Transmission outputNumber of outputs: 2 (Negative terminals of each transmission output channel are connected inside and thus have the same electric potential.) 4mA to 20mA DC or 0mA to 20mA DC input/output isolated type Load resistance: 900  (max.) Linearity: Within 0.08 mA (Output only) Repeatability: Within 0.02 mA (Output only) Output setting: Peracetic acid concentration (Selectable from 0 to 22000 ppm or 0.000 to 2.200) Temperature (Selectable from 10C to 110C) HOLD function: Selectable from the previous value hold and the optional value hold (Setable without HOLD only while calibration
Contact outputNumber of outputs: 5 Contact output: 4 (R1 to R4) Contact type: Non-voltage contact output, relay contact SPST (1a) Contact capacity: 240 V AC 1 A, 30 V DC 1 A (Resistance load) Contact function: Selectable from Upper/lower limit alarm (ON/OFF control) at each measuring objects(concentration, temperature) (Alarm Setting of delay time about measuring objects: 0 seconds to 600 seconds) Contact action: closed when status is in the event. (However, R1 to R3 share a common terminal. R4 and RF share a common terminal) Error alarm contact output (RF): 1 Contact type: Non-voltage contact output, Relay contact, SPDT (1c) Contact capacity: 240 V AC 1 A, 30 V DC 1 A (Resistance load) Contact function: Fail Contact action: Closed when status is normal for C-NO output. Opened when any erroneous status is detected or power is down for C-NO output. C-NC output is opposite action of C-NO. R4 and RF share a common terminal.
Contact inputNumber of input: 1 (external HOLD input) Contact type: No-voltage a contact for open collector Condition: ON resistance: 100 ・ (max.)
・Open-circuit voltage: 24 V DC
・Short-circuit current: 12 mA DC (max.)
Communication outputRS-485 input/output
Self-diagnosis functionCalibration error /Temperture sensor error/Meter error
Power supply24 V DC ±10%
StructureIndoor-use panel installation type Panel case: ABS, Terminal: PBT Panel: IP65 dust and water proof structure
Conforming standardsCE Marking EMC Directive: EN61326-1※2 Class A, Industrial electromagnetic environment FCC rule FCC Part15

Sensor

Product namePeracetic acid sensor※3
Model5800
Measurement principleElectrochemical measurement system
Measurement targetPeracetic acid (CH3COOOH) ※4
Sample temperature range0℃to 45℃ (without freezing)
Supply flow rate500 mL/min to 2000 mL/min※5
PressureWithin 0.1 MPa (constant)※6
Responsibility(To the measurement cell after a supply start) T90 < 5 min※5
Repeatability±100 ppm※7
Ambient temperature0℃ to 45
Liquid contact materialPVC, PTFE, Silicon, PPO, OPP
Internal liquidNeutral phosphate(Food additive)
Cable length5 m to 50 m max.※8

※1 This product does not use for medical equipment.
※2 When the sensor cable, the transmission cable, or the contact input cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.
※3 This product does not use for medical equipment.
※4 Measurements may be affected by a change of the concentrations of hydrogen peroxide
※5 When supply flow rate decreases, responsibility may become slow. Supply flow rate is responsibility when switches from the solution including peracetic acid from the solution which does not include peracetic acid.
※6 When sample pressure includes a change, influence is reflected on instructions level. Install it to become the constant pressure.
※7 Under the constant ambient temperature, sample temperature and flow rate
※8 When the connection cable is extended to 30 m or longer, the surge test specified in the EMC directive for CE marking is not applied.

 

Request for Information

Do you have any questions or requests? Use this form to contact our specialists. * These fields are mandatory.

Related products

ABX Pentra 400 Reagents
More ABX Pentra 400 Reagents

From routine to specific tests

ABX Pentra ML
More ABX Pentra ML

Centralized Validation

CS-600F
More CS-600F

Fiber Optic Type Chemical Concentration Monitor

ESH-01-C-SN
More ESH-01-C-SN

Sanitary Conductivity Sensor (Ferrule Clamp type) for Low Concentrations

FES-310L
More FES-310L

Sanitary Conductivity Sensor (Flow Through type)

FS-01FC-SL Series
More FS-01FC-SL Series

Sanitary Conductivity Sensor (Flow Through type) for Low Concentrations

HD-200
More HD-200

Industrial dissolved oxygen analyzer (Four-Wire Analyzer)

HD-300
More HD-300

Industrial dissolved oxygen analyzer (Two-Wire Transmitter)

HD-480
More HD-480

Industrial dissolved oxygen analyzer (The Slim48 series)

HE-200C
More HE-200C

Industrial electric conductivity meter (Four-Wire Analyzer)

HE-200R
More HE-200R

Industrial electric resistivity meter (Four-Wire Analyzer)

HE-300C
More HE-300C

Industrial electric conductivity meter (Two-Wire Transmitter)

HE-300R
More HE-300R

Industrial electric resistivity meter (Two-Wire Transmitter)

HE-480C
More HE-480C

Industrial conductivity meter (low concentration type)

HE-480C-GC
More HE-480C-GC

Carbon Sensor Conductivity Meter (Low concentration type)

HE-480H
More HE-480H

Industrial conductivity meter (high concentration type)

HE-480R(W)
More HE-480R(W)

Industrial resistivity meter

HE-960CA
More HE-960CA

Citric Acid Monitor

HE-960CW
More HE-960CW

2-channel Sanitary Conductivity Meter (Low Concentration type)

HE-960H-TM
More HE-960H-TM

Wide range TMAH Concentration Monitor

HE-960H-TM-S
More HE-960H-TM-S

High Precision TMAH Concentration Monitor

HE-960HC
More HE-960HC

Carbon Sensor Conductivity Meter (High concentration type)

HE-960HI
More HE-960HI

Sanitary Conductivity Meter (Wide-range type)

HE-960LC
More HE-960LC

Carbon Sensor Conductivity Meter

HE-960R-GC(W)
More HE-960R-GC(W)

Carbon Sensor Resistivity Meter

HE-960RW
More HE-960RW

Industrial resistivity meter

HE-960RW-GC(W)
More HE-960RW-GC(W)

2-Channel Resistivity Meter

HE-960TM
More HE-960TM

TMAH Conductivity Meter. Perfect for Controlling TMAH Developer Concentrations

HE-Z-100T
More HE-Z-100T

High Resistivity Meter

HF HD-960L
More HF HD-960L

Dissolved Oxygen Monitor in Low Concentration

HF-960H
More HF-960H

HF / HCl Concentration Monitor

HF-960M
More HF-960M

Low Concentration Type HF/HCl/NH3 Concentration Monitor

HF-SP-CU
More HF-SP-CU

2-channel High Precision HF Concentration Monitor

HO-200
More HO-200

Industrial ORP meter (Four-Wire Analyzer)

HP-300
More HP-300

Industrial pH meter (Two-Wire Transmitter)