FLIMera

SPAD array imaging camera for dynamic FLIM studies at real time video rates

A New Concept in FLIM Imaging

The HORIBA FLIMera camera is a new concept in FLIM technology. It is a wide field imaging camera, rather than a confocal point scanning system, with the intrinsic benefit of being able to study FLIM dynamics at video rates with a simple camera technology.

FLIMera Video (1:43)

Segment: Scientific
Manufacturing Company: HORIBA Scientific
  • TCSPC per pixel architecture offers 24,576 simultaneous decays
  • Complex multicomponent lifetimes
  • Decay kinetics are acquired directly.
  • Sample analysis with up to 5 exponential decays
  • EzTime Image simple and efficient software interface
  • Perfect for complex and sophisticated molecular analysis like live cell dynamics and detection of biomarkers for disease diagnostics.

 

Advances in CMOS technology have led to the development of imaging sensors, based on arrays of pixels, with each pixel containing a single-photon avalanche photodiode (SPAD) and its associated timing electronics, based on a time to digital converter (TDC).

This enables rapid (video rate) fluorescence lifetime determination based on the time-correlated single photon counting technique (TCSPC) realized independently in each pixel (Figure 1).

Figure 1: The SPAD and TDC couple

A 192 x 128 pixel image sensor, implemented in 40 nm CMOS technology, is incorporated in a widefield epifluorescence microscope set-up. The sensor has a 13% fill-factor and each 18.4 x 9.2 μm pixel contains a TDC with a resolution <40 ps. This enables up to 24,576 simultaneous fluorescence lifetime measurements each with 4,096 time bins. Through dedicated firmware and the HORIBA EzTime Image software implementation, the fluorescence intensity and the average lifetime as well as the phasor plot generated from the TCSPC imaging measurement, can be simultaneously displayed in real time at video (>30 fps) rates (Figure 2).

Figure 2: Four simultaneous datasets presented

 

Modes of operation

The FLIMera is designed for use with HORIBA’s highly intuitive EzTime Image software. This software is used for FLIMera control, data acquisition and analysis. FLIMera provides 4 modes of operation.

  • Manual – User start and stop of acquisition, providing TCSPC intensity image and FLIM data for lifetime analysis.
  • Timed – User defined run time for acquisition, providing TCSPC intensity image and FLIM data for lifetime analysis.
  • Streaming to HDF5 file – TCSPC data can be streamed, for a user-determined time period, to a HDF5 file. This contains full records for each photon in every pixel, so no data is lost, and can be used to reconstruct frames for full decay analysis.
  • Phasor Plot – Complementing the histogram representation is the ability to show and select lifetime data in the form of a phasor plot in real time, as seen in Figure 3. The phasor plot requires initial calibration using a lifetime standard.

 

Figure 3: Phasor plot

 

The video-rate capability is demonstrated using standard samples and FUN-1 labelled yeast cells (Figure 4).


Figure 4: Sequence of images extracted from FUN-1 labeled yeast cell lifetime video https://youtu.be/1Fu7VOCsHuA

 

Figure 5 a: Decay from DeltaFLEX cuvette system

 

Figure 5 b: Decay from just one of 24,578 SPAD pixels demonstrates the very high resolution and TCSPC fidelity of FLIMera

FLIM and HORIBA

The novelty of the in-pixel detection and timing technology enables a widefield imaging approach, which significantly reduces data acquisition times enabling the study of dynamic events. FLIMera contributes to HORIBA’s long history in the field of fluorescence measurement; recognized by winning the prestigious Institute of Physics Business Innovation Award.

 

FLIMera Camera Specifications
Modality Widefield Time-Domain TCSPC
Sensor SPAD CMOS with In-Pixel TDC
Sensor Wavelength Range 400 to 900 nm
Max Total Count Rate Up to 295 Mcps theoretical
Max Pixel Count Rate 12 kcps
Image Array 192 x 128 pixels
Frame Rate (Max.) 30 fps
Fill Factor 13%
Lifetime Range From 200 ps to 20 ns
Lifetime Resolution Up to 4096 time bins of 50 ps
Connection Type C-Mount
Electronics Interface Included HORIBA FLIMera Base Unit (includes laser synch input TTL)
Software Included HORIBA EzTime Image
Required Components Pulsed laser source
Light Source Options DeltaDiode Lasers

 

 

FLASH-FLIM measurements with the FLIMera TCSPC Camera
FLASH-FLIM measurements with the FLIMera TCSPC Camera
Recent developments CMOS technology allow widefield lifetime imaging, with the ability to measure FLIM in real time, to be employed to investigate mobile samples and kinetics, as well as remote imaging.

Request for Information

Do you have any questions or requests? Use this form to contact our specialists.

* These fields are mandatory.

Related products

Aqualog - Water Treatment Plant Analyzer
Aqualog - Water Treatment Plant Analyzer

Automated Organic Analysis & Early Warning Sentinel

Aqualog Datastream
Aqualog Datastream

For Instant Water Quality Reports

CFD-2G
CFD-2G

Amplifier-Discriminator

DAS6
DAS6

Decay Analysis Software

DeltaDiode
DeltaDiode

TCSPC Pulsed Sources

DeltaFlex
DeltaFlex

TCSPC/MCS Fluorescence Lifetime System

DeltaPro
DeltaPro

TCSPC Lifetime Fluorometer

Duetta
Duetta

Fluorescence and Absorbance Spectrometer

Fluorolog-QM
Fluorolog-QM

Modular Research Fluorometer for Lifetime and Steady State Measurements

FluoroMax Plus
FluoroMax Plus

Steady State and Lifetime Benchtop Spectrofluorometer

Hybrid Picosecond Photon Detector (HPPD) Series
Hybrid Picosecond Photon Detector (HPPD) Series

HORIBA’s latest development in TCSPC detector technology

Nanolog
Nanolog

Steady State and Lifetime Nanotechnology EEM Spectrofluorometer

Nanosizer
Nanosizer

For Single‐Walled Carbon Nanotube Excitation‐Emission Map Simulation and Analysis

PPD Photon Counting Detector
PPD Photon Counting Detector

Single photons detection with picosecond accuracy

QuantaPhi-2
QuantaPhi-2

PLQY Integrating Sphere

SpectraLED
SpectraLED

LED Phosphorescence Light Sources

Ultima
Ultima

Ultra Fast TCSPC Lifetime Fluorometer

Universal Fiber Coupling Solution
Universal Fiber Coupling Solution

Connect any of our steady state and hybrid fluorometers to virtually any upright or inverted microscope!