X-ray Fluorescence Sulfur-in-Oil Analyzer

SLFA-6000

HORIBA Scientific, a market leader in sulfur-in-oil analysis, announces the launch of the new SLFA-6100/6800 Energy Dispersive X-Ray Fluorescence Analyzer, which measures sulfur in oil ranging from 5ppm to 9.9999%.  This new, compact, and accurate analyzer meets the needs of anyone wishing to conform to ASTM D4294, ISO 8754 or JIS K2541/B7995.

 

Segment: Scientific
Division: Elemental Analysis
Base product
Manufacturing Company: HORIBA Ltd.

The SLFA-6X00 series has an optimized user interface, which includes full-color monitor, USB output, data printout mode option and smaller footprint with a sophisticated look.  A shutter shield has once again been adopted to prevent X-Ray leakage, along with a new key switch function and a newly designed turntable.

Speed:

The measurement is set between 10 to 600 seconds.

Automation:

Up to 8 samples on SLFA-6800 turntable are analyzed with the pre-set condition.

Simple operation:

After selecting the calibration curves and measurement conditions (or select the correct calibration curve using the “A” mode), simply press the “MEAS” button to start the measurement.

Accuracy:

The software allows up to 5 sets of 3 calibration curves, to increase the accuracy and usability.

Measurement Specifications

Measurement principleX-ray Fluorescence Analysis Method
Measurement sampleSulfur in petroleum products such as heavy oil, naphtha, crude oil and light oil
Measurement range5ppm - 9.9999 %
Repeatability

5 ppm or less with a 1% sulfur sample,

1.6 ppm or less with a 0% sulfur sample

C/H error correction± 50 ppm or less per C/H (with a 1 % sulfur sample)
Lower detection limit

5 ppm or less *

* 3 times the standard deviation with a 0% sample

Number of calibration curvesUp to 15 calibration curves
Calibration curve orderLinear or Quadratic (both automatic selection and manual settings are available)
Amount and number of samples

4 - 10 mL, 1 sample(SLFA-6100)

4 - 10 mL, 8 samples(SLFA-6800)

Measurement time10 - 600 sec
Data outputPrintout, USB memory stick, USB cable connected to PC
Spectrum measurementEnergy Range: 0 - 10 keV, spectrum analysisto verify instrument performances
Operating temperature+ 5 ˚C to + 40 ˚C (+ 41 ˚F to 104 ˚F)
Operating humidity80% max relative humidity in temperature range
+ 5 ˚C to + 30 ˚C (+ 41 ˚F to 86 ˚F)
Linear decrease to 50% relative humidity in temperature range
+ 31 ˚C to + 40 ˚C (+ 88 ˚F to 104 ˚F)
Power supplyAC 100 - 240 V +/- 10%, 50/60 Hz
Power consumption150 VA
Dimentions
[W x D x H]
403 x 468 x 210 mm
Weight

Approx. 21 kg (SLFA-6100)
Approx. 23 kg (SLFA-6800)

 

Conformity Standards

 ASTM D4294 (USA), ISO 8754, JIS K2541/B7995