Industrial simplified fluoride ion concentration meter HC-200F (Four-Wire Analyzer)

HC-200F (Four-Wire Analyzer)

 

 

Segment: Process And Environment
Division: Process Water
Base product
Manufacturing Company: HORIBA Advanced Techno Co. Ltd.

 

  • Suitable for fluoride ion monitoring in effluent from factories, e.g., those of semiconductor FPD and glass manufacturers
  • 0 to 10,000 mg/L wide measuring range (10-range switching)

 

 

ModelHC-200F
Combined sensorFluoride ion electrode 1009
Measurement rangeConcentration:
 0 mg/L to 10000 mg/L (Display range: 0 mg/L to 11000 mg/L)
 The selectable range: 10000 ,5000 ,2000 ,1000 ,500 ,200 ,100 ,50 ,20.0 ,10.0 mg/L
Temperature: 0°C to 100°C (Display range: -10°C to 110°C )
Transmission outputNumber of output: 2
(The negative terminals for transmission outputs are internally connected at the same electric potential)
Output type: 4 mA to 20 mA DC: input/output isolated type
Load resistance: Maximum: 900 Ω
Contact outputNumber of output: 3
Output type: No-voltage contact output
Contact type: Relay contact; SPDT (1c)
Output capacity: 250 VAC 3 A, 30 VDC 3 A (resistance load)
Cleaning outputNumber of output: 1
Output type: AC power control output ( Applied power supply voltage)
Contact type: Relay contact; SPST (1a)
Output contact capacity: 250 VAC 3 A, 30 VDC 3 A (resistance load)
External instrument: Solenoid valve for cleaning control
Contact inputNumber of inputs: 1
Contact type: No-voltage "a" contact for open collector
Communication functionCommunication type: RS-485
Signal type:
 2 wire system, isolated from the input circuit
 Not isolated from transmission circuit
Temperature compensationApplicable temperature element:
 Platinum resistor: 1kΩ (0°C)
 Positive relation resistor with temperature: 10kΩ(25°C)
Temperature compensation range: 0 °C to 100°C
CalibrationNumber of calibration points: Selectable from 1, and 2 points
Self-checkCalibration error
Electrode diagnostic error
Meter error
Operating temperature range-20°C to 55°C (without freeze)
Power supplyPower supply voltage range: 90 V to 264 VAC 50/60 Hz
Power consumption: 15VA(max)
Compatible standardsCE marking, FCC Rules
StructureInstallation: Outdoor installation type
Installation method: Mounted on 50A pole or wall
Protection code: IP65 IEC60529, JIS C0920
Case material: Aluminum alloy (coated with epoxy-denatured melamine resin)
External dimensions180 (W) x 155 (H) x 115 (D) mm (excluding the fittings)
MassMain body: Approx. 3.5 kg; cover and fittings: Approx. 1 kg
Product nameFluoride ion electrode
Model1009
Sample water conditionspH range:
 4 to 8 pH (at 0.2 mg/L)
 4 to 10 pH (at 20 mg/L)
 4 to 12 pH (at 2000 mg/L)
Temperature range: 0 to 40°C
Electric conductivity: Over 500 μS/cm
Flow rate range: 1 to 20 cm/sec.
Electrode structureStructure: Submergible type
Response film: Lanthanum fluoride
Comparative electrode: Ag/AgCl, Internal solution, KCL 3.3 mol/L, Replenishment type
Liquid junction: Ceramic double junction
Temperature compensation element: Pt1000Ω (0°C)
cable length: 5 m
External dimensions12Φ × 175 (L) mm(cable and projection excluded)
MassApprox. 200g

 

REQUEST FOR INFORMATION